summaryrefslogtreecommitdiffstats
path: root/_ont/ont-fs-com-gpon-onu-stick-with-mac.md
blob: 254ecd56e1c89bce8aa9d9a038cd851264f1033e (plain) (blame)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
470
471
472
473
474
475
476
477
478
479
480
481
482
483
484
---
title: ONT FS.com GPON ONU Stick with MAC (GPON-ONU-34-20BI)
has_children: false
alias: SourcePhotonics SPS-34-24T-HP-TDFO
parent: ONT FS.com
layout: default
---

# Hardware Specifications

|                  |                                          |
| ---------------- | ---------------------------------------- |
| Vendor/Brand     | FS.com                                   |
| Model            | GPON-ONU-34-20BI                         |
| ODM              | ✅                                       |
| Chipset          | Lantiq PEB98035                          |
| CPU              | MIPS 34Kc interAptiv                     |
| CPU Clock        | 400MHz                                   |
| Flash            | 16 MB                                    |
| RAM              | 64 MB                                    |
| Bootloader       | U-Boot 2011.12-lantiq-gpon-1.2.24        |
| System           | OpenWRT 14.07_ltq (Kernel 3.10.49)       |
| Load addr        | 0x80800000                               |
| HSGMII           | Yes                                      |
| Optics           | SC/APC                                   |
| IP address       | 192.168.1.10                             |
| Web Gui          |                                          |
| SSH              | ✅ user `ONTUSER`, password `7sp!lwUBz1` |
| Telnet           |                                          |
| Serial           | ✅ on SFP                                |
| Serial baud      | 115200                                   |
| Serial encoding  | 8-N-1                                    |
| Form Factor      | miniONT SFP                              |

{% include image.html file="ont-fs.jpg" alt="ONT FS.com GPON ONU" caption="ONT FS.com GPON ONU" %}
{% include image.html file="ont-fs-box.jpg" alt="ONT FS.com GPON ONU in the box" caption="ONT FS.com GPON ONU in the box" %}

## Possible clones

- SourcePhotonics SPS-34-24T-HP-TDFO

## Firmware is interchangeable with:

- [Huawei MA5671A](/ont-huawei-ma5671a)
- [Nokia G-010S-P](/ont-nokia-g-010s-p)
- [Hilink HL23446](/ont-hilink-hl23446)
- {:.text-red-200 } Dasan H650SFP 
- {:.text-red-200 } DpOptics D23446  
- {:.text-red-200 } Photonics SPS-34-24T-HP-TDFO

## Serial

The stick has a TTL 3.3v UART console (configured as 115200 8-N-1) that can be accessed from the SFP connector.

| USB TTL(UART) Adapter | SFP 20pins Molex connector |
| --------------------- | -------------------------- |
| 3.3V                  | pin #15 and #16            |
| TX                    | pin #2                     |
| RX                    | pin #7                     |
| GND                   | pin #14                    |


{% include alert.html content="Some USB TTL adapters label TX and RX pins the other way around: try to swap them if the connection doesn't work." alert="Note"  icon="svg-warning" color="yellow" %}

# General Settings and Useful Commands

## Bootloader unlock from shell
{% include alert.html content="It is strongly recommended that you unlock the bootloader before making any major changes to the firmware." alert="Warning"  icon="svg-warning" color="yellow" %}
```sh
fw_setenv bootdelay 5
fw_setenv asc0 0
fw_setenv preboot "gpio set 3;gpio input 2;gpio input 105;gpio input 106;gpio input 107;gpio input 108"
```

## Emergency bootloader unlock via TTL serial

{% include alert.html content="This is not necessary if you have already unlocked the bootloader from the shell as specified above." alert="Warning"  icon="svg-warning" color="yellow" %}

If for for some reason you are in the situation where you do not have a bootable firmware on your SFP stick you can do an emergency unlock via TTL serial.

To perform the emergency unlock is necessary to have:
- TTL-USB adapter
- SFP adapter to connect the TTL-USB cables to the SFP stick

The electrical connections are the same as those of the Huawei MA5671A, see the [Huawei root guide](/ont-huawei-ma5671a-root-web) for accurate details on how to connect the TTL-USB to the SFP adapter.

When you are ready with everything plugged in you need to press the button below. A window will open that will execute the emergency unlock.

{: .text-center .fs-6 }
<button id="start-button" class="btn btn-blue" data-jtd-toggle="modal" data-jtd-target="#root-modal" disabled>Start emergency unlock!</button>
{% include root_lantiq.html modelName="FS GPON ONU Stick" unlockHuaweiShell=false %}

<div id="browser-error" style="display:none">{% include alert.html content="This browser is not compatible with the emergency unlock procedure. See the <a href='https://developer.mozilla.org/en-US/docs/Web/API/Web_Serial_API#browser_compatibility'>Browser compatibility</a>" alert="Note"  icon="svg-warning" color="red" %}</div>
<noscript>
{% include alert.html content="Your browser does not support JavaScript!" alert="Note"  icon="svg-warning" color="red" %}
</noscript>


## Setting S/N
```sh
set_serial_number ABCD12345678
```
Or:
```sh
sfp_i2c -i8 -s "ABCD12345678"
```

## Checking whether the S/N has been correctly set
```sh
fw_printenv | grep nSerial
```
Or:
```sh
sfp_i2c -g
```

## Setting PLOAM Password
Software 6BA1896SPLQA41 and earlier (See [Carlito Firmware](/ont-huawei-ma5671a-carlito))
```sh
fw_setenv nPassword "0x30 0x31 0x32 0x33 0x34 0x35 0x36 0x37 0x38 0x39"
```

Software 6BA1896SPLQA42 and after:
```sh
sfp_i2c -i11 -s "1234567890"
```

## Setting LOID and Checkcode Password
Software 6BA1896SPLQA41 and earlier (See [Carlito Firmware](/ont-huawei-ma5671a-carlito))
```sh
fw_setenv omci_loid 1234567890
fw_setenv omci_lpwd password01
```

Software 6BA1896SPLQA42 and after:
```sh
sfp_i2c -i9 -s "1234567890"
sfp_i2c -i10 -s "password01"
```

## Setting Eqipment ID (ME 257)
```sh
sfp_i2c -i6 -s "YOUR_EQUIPMENT_ID"
```

## Setting Vendor ID (ME 256)
```sh
sfp_i2c -i7 -s "YOUR_VENDOR_ID"
```

## Changing ONU hardware version (ME 256)
```sh
sed 's/256 0 HWTC 0000000000000/256 0 YOUR_VENDOR_ID YOUR_ONU_VERSION/' /rom/etc/mibs/data_1g_8q.ini > /etc/mibs/data_1g_8q.ini
```

## Restore the default ONU hardware version (ME 256)
```sh
cat /rom/etc/mibs/data_1g_8q.ini > /etc/mibs/data_1g_8q.ini
```

## Enabling `data_1g_8q_us1280_ds512.ini` OMCI MIB file for 2500 Mbps profiles
{% include alert.html content="The patch below is only compatible with the firmware version `6BA1896SPLQA42`" alert="Info" icon="svg-info" color="blue" %}
{% include alert.html content="If you need to set the ONU version remember that you will have to do it using the MIB file `/etc/mibs/data_1g_8q_us1280_ds512.ini` instead of `/etc/mibs/data_1g_8q.ini`" alert="Info" icon="svg-info" color="blue" %}

The MIB file `data_1g_8q_us1280_ds512.ini` is very useful to avoid performance problems in situations where 2500 Mbps speed profiles are used, to enable it you need to run this command:
```sh
fw_setenv mib_file data_1g_8q_us1280_ds512.ini
```

## Using custom OMCI MIB file
{% include alert.html content="If you need to set the ONU version remember that you will have to do it using your custom MIB file instead of `/etc/mibs/data_1g_8q.ini`" alert="Info" icon="svg-info" color="blue" %}

You have to copy the MIB file to /etc/mibs and then run this command:
```sh
fw_setenv mib_file YOUR_MIB_FILENAME
```

## Changing image software version (ME 7)
{% include alert.html content="The patch below is only compatible with the firmware version `6BA1896SPLQA42`" alert="Info" icon="svg-info" color="blue" %}

The image version normally couldn't be changed because it was hard-coded into the `/opt/lantiq/bin/omcid` binary, 
so you need to then modify the binary with the following hex patch which removes the hardcoded version.

```
< 000084c0: 9a43 931f f760 d840 9b64 f760 d864 1a00  .C...`.@.d.`.d..
< 000084d0: 1acf 6500 1a20 2268 940a 2205 b468 1a00  ..e.. "h.."..h..
---
> 000084c0: 9a43 931f f760 d840 9b64 f760 d864 6500  .C...`.@.d.`.de.
> 000084d0: 6500 6500 1a20 2268 940a 2205 b468 1a00  e.e.. "h.."..h..

```

{% include alert.html content="Proceed only if your `md5sum /opt/lantiq/bin/omcid` has the correct checksum `7e97163e24c9cb39439589c65b438168`" alert="Info" icon="svg-info" color="blue" %}

This is the patch, encoded in base64
```
QlNESUZGNDA1AAAAAAAAAD4AAAAAAAAA2C8JAAAAAABCWmg5MUFZJlNZYqnvBwAACFBSQWAAAMAA
AAgAQCAAMQwIIwjImgDOdMvi7kinChIMVT3g4EJaaDkxQVkmU1lrJSbUAACFTAjAACAAAAiCAAAI
IABQYAFKQ01INxUgd6Soj2JURm8pUR8XckU4UJBrJSbUQlpoORdyRThQkAAAAAA=
```
Save it on your computer (not on the stick) as `omcid_patch.base64`, then run:
```sh
base64 -d omcid_patch.base64 > omcid.bspatch
bspatch <your_original_omcid> omcid omcid.bspatch
```
{% include alert.html content="if you don't have bspatch installed, most distributions includes it in bsdiff package" alert="Info" icon="svg-info" color="blue" %}

After patching the resulting patched `omcid` should have an md5 checksum of `525139425009c4138e92766645dad7d0`.
If that also checks, go on making a backup copy of your original `omcid` on the stick.

```sh
cd /opt/lantiq/bin
cp omcid omcid.original
```

Now you have to use SCP to copy the modified `omcid` binary in `/opt/lantiq/bin/omcid`.
Before restarting the stick and applying changes, make sure `omcid` has its execution bit set, then reboot the stick and change the image version with the following command:

```sh
chmod ugo+x /opt/lantiq/bin/omcid
```


Is also a good time to set the image0/image1_version. Crash has reported if they are not set correctly before reboot.
```sh
fw_setenv image0_version YOUR_IMAGE0_VERSION
fw_setenv image1_version YOUR_IMAGE1_VERSION
```

Now you can restart the stick.
{% include alert.html content="Be aware that sometimes `omcid` can rewrite the two variables when runs in non patched state. After reboot, double check the values you put are still there." alert="Info" icon="svg-info" color="blue" %}

## Setting Lantiq MAC address
```sh
uci set network.lct.macaddr=00:06:B5:07:D6:04
uci set network.host.macaddr=00:06:B5:07:D8:04
uci commit network.lct.macaddr=00:06:B5:07:D6:04
uci commit network.host.macaddr=00:06:B5:07:D8:04
```

## Setting Lantiq IP address
```sh
fw_setenv ipaddr 192.168.20.60
fw_setenv gatewayip 192.168.20.1
```

## Reading all EEPROM
```sh
sfp_i2c -r
```

## Getting Firmware version
```sh
strings /opt/lantiq/bin/omcid | grep ^software_Version | awk -F[=,] '{print $2}'
```

## Getting Firmware build time
```sh
strings /opt/lantiq/bin/omcid | grep compiled
```

## Rebooting the ONU
```sh
reboot
```

## Checking whether the connection with the OLT was successful (O5 state)

```shell
onu ploamsg
```

## Disable RX_LOS status
{% include alert.html content="The patch below is only compatible with the firmware version `6BA1896SPLQA42`" alert="Info" icon="svg-info" color="blue" %}

Some switches/routers (e.g. Mikrotik) do not allow access to the magament interface without the fiber connected because the SFP reports RX_LOS status, it's possible to modify the `mod_optic.ko` driver to spoof non RX_LOS status by setting PIN 8 (RX_LOS) to be always low.

This is the change to be made in hex format:

```
< 00013740: 2404 0003 2405 0001 0c00 0000 ac43 0980  $...$........C..
---
> 00013740: 2404 0003 2405 0000 0c00 0000 ac43 0980  $...$........C..
```

{% include alert.html content="Proceed only if your `md5sum /lib/modules/3.10.49/mod_optic.ko` has the correct checksum `7c718c3410c4120fe98fa7a9a5c6c407`" alert="Info" icon="svg-info" color="blue" %}

This is the patch, encoded in base64:
```
QlNESUZGNDA2AAAAAAAAADYAAAAAAAAAXEEFAAAAAABCWmg5MUFZJlNZ5TTrjgAAB+ZARjAEACAA
AARAACAAMQZMQRppiFkgKGTeXi7kinChIcpp1xxCWmg5MUFZJlNZcaVLvQABOOCAwAAAAQAIAAig
ACClRgZoMhUf9JKbgIk3hdyRThQkHGlS70BCWmg5F3JFOFCQAAAAAA==
```

Save it on your computer (not on the stick) as `mod_optic.base64`, then run:
```sh
base64 -d mod_optic.base64 > mod_optic.bspatch
bspatch <your_original_mod_optic.ko> mod_optic.ko mod_optic.bspatch
```
{% include alert.html content="if you don't have bspatch installed, most distributions includes it in bsdiff package" alert="Info" icon="svg-info" color="blue" %}

After patching the resulting patched `mod_optic.ko` should have an md5 checksum of `e14a5a70b023873853afe920870f076e`.
If that also checks, go on making a backup copy of your original `mod_optic.ko` on the stick.

```sh
cd /lib/modules/3.10.49/
cp mod_optic.ko mod_optic.ko.original
```

Now you have to use SCP to copy the modified `mod_optic.ko` kernel module in `/lib/modules/3.10.49/mod_optic.ko`.

## List of software versions
- 6BA1896SPLQA13 (Dec 16 2016)
- 6BA1896SPLQA41
- 6BA1896SPLQA42 (Sep 18 2021)

## List of partitions
When image0 is committed: 

| dev  | size     | erasesize | name          |
| ---- | -------- | --------- | ------------- |
| mtd0 | 00040000 | 00010000  | "uboot"       |
| mtd1 | 00080000 | 00010000  | "uboot_env"   |
| mtd2 | 00740000 | 00010000  | "linux"       |
| mtd3 | 0061eedc | 00010000  | "rootfs"      |
| mtd4 | 00370000 | 00010000  | "rootfs_data" |
| mtd5 | 00800000 | 00010000  | "image1"      |

When image1 is committed: 

| dev  | size     | erasesize | name          |
| ---- | -------- | --------- | ------------- |
| mtd0 | 00040000 | 00010000  | "uboot"       |
| mtd1 | 00080000 | 00010000  | "uboot_env"   |
| mtd2 | 00740000 | 00010000  | "image0"      |
| mtd3 | 00800000 | 00010000  | "linux"       |
| mtd4 | 006d8077 | 00010000  | "rootfs"      |
| mtd5 | 00410000 | 00010000  | "rootfs_data" |

## EEPROM (I2C slave simulated EEPROM)
The FS GPON-ONU-34-20BI does not have a physical EEPROM, the Falcon SOC emulates an EEPROM by exposing it on the I2C interface as required by the SFF-8472 specification.

On the I2C interface there will be two memories of 256 bytes each at the addresses `1010000X (A0h)` and `1010001X (A2h)`, however in reality the memory available from the emulated EEPROM will be 640 bytes each but only the first 256 bytes will be exposed in the I2C interface.

The FS GPON-ONU-34-20BI stores the content of the emulated EEPROM in U-Boot env variables to restore it after a reboot:

- `EEPROM0 (A0h)` stored in U-Boot env variable `sfp_a0_low_128`
- `EEPROM1 (A2h)` stored in U-Boot env variable `sfp_a2_info`

### EEPROM0 layout

| address | size | name                              | default value                                                                                           | description                                                         |
| ------- | ---- | --------------------------------- | ------------------------------------------------------------------------------------------------------- | ------------------------------------------------------------------- |
|         |      | **BASE ID FIELDS (SFF-8472)**     |                                                                                                         |                                                                     |
| 0       | 1    | Identifier                        | `0x03` (SFP)                                                                                            | Type of transceiver                                                 |
| 1       | 1    | Ext identifier                    | `0x04` (MOD_DEF 4)                                                                                      | Additional information about the transceiver                        |
| 2       | 1    | Connector                         | `0x01` (SC)                                                                                             | Type of media connector                                             |
| 3-10    | 8    | Transceiver                       | `0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00`                                                               | Code for optical compatibility                                      |
| 11      | 1    | Encoding                          | `0x03` (NRZ)                                                                                            | High speed serial encoding algorithm                                |
| 12      | 1    | Signaling Rate, Nominal           | `0x0C` (1.244Gbps)                                                                                      | Nominal signaling rate                                              |
| 13      | 1    | Rate Identifier                   | `0x00` (Not used)                                                                                       | Type of rate select functionality                                   |
| 14      | 1    | Length (SMF,km)                   | `0x14` (20 km)                                                                                          | Link length supported for single-mode fiber, units of km            |
| 15      | 1    | Length (SMF)                      | `0xC8` (200 x 100m)                                                                                     | Link length supported for single-mode fiber, units of 100 m         |
| 16      | 1    | Length (50 um, OM2)               | `0x00` (No support)                                                                                     | Link length supported for 50 um OM2 fiber, units of 10 m            |
| 17      | 1    | Length (62.5 um, OM1)             | `0x00` (No support)                                                                                     | Link length supported for 62.5 um OM1 fiber, units of 10 m          |
| 18      | 1    | Length copper cable               | `0x00` (No support)                                                                                     | Link length supported for copper or direct attach cable, units of m |
| 19      | 1    | Length (50 um, OM3)               | `0x00` (No support)                                                                                     | Link length supported for 50 um OM3 fiber, units of 10 m            |
| 20-35   | 16   | Vendor name                       | `0x46 0x53 0x20 0x20 0x20 0x20 0x20 0x20 0x20 0x20 0x20 0x20 0x20 0x20 0x20 0x20` (FS)                  | SFP vendor name (ASCII)                                             |
| 36      | 1    | Transceiver                       | `0x00` (No support)                                                                                     | Code for optical compatibility                                      |
| 37-39   | 3    | Vendor OUI                        | `0x00 0x00 0x00` (No specified)                                                                         | SFP vendor IEEE company ID                                          |
| 40-55   | 16   | Vendor PN                         | `0x47 0x50 0x4F 0x4E 0x2D 0x4F 0x4E 0x55 0x2D 0x33 0x34 0x2D 0x32 0x30 0x42 0x49` (GPON-ONU-34-20BI)    | Part number provided by SFP vendor (ASCII)                          |
| 56-59   | 4    | Vendor rev                        | `0x30 0x31 0x20 0x20` (01)                                                                              | Revision level for part number provided by vendor (ASCII)           |
| 60-61   | 2    | Wavelength                        | `0x05 0x1E` (1310nm TX)                                                                                 | Laser wavelength                                                    |
| 62      | 1    | Fibre Channel Speed 2             | `0x00` (No support)                                                                                     | Transceiver's Fibre Channel speed capabilities                      |
| 63      | 1    | CC_BASE                           |                                                                                                         | Check code for Base ID Fields (addresses 0 to 62)                   |
|         |      | **EXTENDED ID FIELDS (SFF-8472)** |                                                                                                         |                                                                     |
| 64-65   | 2    | Options                           | `0x00 0x1A` (TX DISABLE, TX FAULT, RX LOS)                                                              | Indicates which optional transceiver signals are implemented        |
| 66      | 1    | Signaling Rate, max               | `0x00` (No specified)                                                                                   | Upper signaling rate margin, units of %                             |
| 67      | 1    | Signaling Rate, min               | `0x00` (No specified)                                                                                   | Lower signaling rate margin, units of %                             |
| 68-83   | 16   | Vendor SN                         | Unique in each SFP                                                                                      | Serial number provided by vendor (ASCII)                            |
| 84-91   | 8    | Date code                         | Unique in each SFP                                                                                      | Vendor's manufacturing date code                                    |
| 92      | 1    | Diagnostic Monitoring Type        | `0x68` (Digital diagnostic, Internally calibrated, Received average power type)                         | Indicates which type of diagnostic monitoring is implemented        |
| 93      | 1    | Enhanced Options                  | `0xF0` (Alarm/warning flags, soft TX_DISABLE control, soft TX_FAULT monitoring, soft RX_LOS monitoring) | Indicates which optional enhanced features are implemented          |
| 94      | 1    | SFF-8472 Compliance               | `0x05` (Rev 11.0 of SFF-8472)                                                                           | Indicates which revision of SFF-8472 the transceiver complies with  |
| 95      | 1    | CC_EXT                            |                                                                                                         | Check code for the Extended ID Fields (addresses 64 to 94)          |
|         |      | **VENDOR SPECIFIC FIELDS**        |                                                                                                         |                                                                     |
| 96-127  | 32   | Vendor data                       | `0x20 0x20 0x20...` (Not used)                                                                          | Vendor specifc data (ASCII)                                         |
| 128-255 | 128  | Reserved                          | `0x00 0x00 0x00...`                                                                                     | Reserved                                                            |
|         |      | **EXTRA EEPROM FIELDS**           |                                                                                                         | **Not exposed to I2C interface**                                    |
| 256-639 | 384  | Reserved                          | `0x00 0x00 0x00...`                                                                                     | Reserved                                                            |


### EEPROM1 layout

| address | size | name                              | default value                                                                               | description                                                       |
| ------- | ---- | --------------------------------- | ------------------------------------------------------------------------------------------- | ----------------------------------------------------------------- |
|         |      | **DIAGNOSTIC AND CONTROL FIELDS** |                                                                                             |                                                                   |
| 0-1     | 2    | Temp High Alarm                   | `0x5F 0x00` (95℃)                                                                           |                                                                   |
| 2-3     | 2    | Temp Low Alarm                    | `0xCE 0x00` (-50℃)                                                                          |                                                                   |
| 4-5     | 2    | Temp High Warning                 | `0x5A 0x00` (90℃)                                                                           |                                                                   |
| 6-7     | 2    | Temp Low Warning                  | `0xD3 0x00` (-45℃)                                                                          |                                                                   |
| 8-9     | 2    | Voltage High Alarm                | `0x8C 0xA0` (3.6V)                                                                          |                                                                   |
| 10-11   | 2    | Voltage Low Alarm                 | `0x75 0x30` (3.0V)                                                                          |                                                                   |
| 12-13   | 2    | Voltage High Warning              | `0x88 0xB8` (3.5V)                                                                          |                                                                   |
| 14-15   | 2    | Voltage Low Warning               | `0x79 0x18` (3.1V)                                                                          |                                                                   |
| 16-17   | 2    | Bias High Alarm                   | `0xAF 0xC8` (90mA)                                                                          |                                                                   |
| 18-19   | 2    | Bias Low Alarm                    | `0x00 0x00` (0mA)                                                                           |                                                                   |
| 20-21   | 2    | Bias High Warning                 | `0x88 0xB8` (70mA)                                                                          |                                                                   |
| 22-23   | 2    | Bias Low Warning                  | `0x00 0x00` (0mA)                                                                           |                                                                   |
| 24-25   | 2    | TX Power High Alarm               | `0xF6 0x77` (8dBm)                                                                          | Value expressed in watts subunits                                 |
| 26-27   | 2    | TX Power Low Alarm                | `0x15 0xF7` (-2.5dBm)                                                                       | Value expressed in watts subunits                                 |
| 28-29   | 2    | TX Power High Warning             | `0xC3 0xC6` (7dBm)                                                                          | Value expressed in watts subunits                                 |
| 30-31   | 2    | TX Power Low Warning              | `0x1B 0xA7` (-1.5dBm)                                                                       | Value expressed in watts subunits                                 |
| 32-33   | 2    | RX Power High Alarm               | `0x0C 0x5A` (-5dBm)                                                                         | Value expressed in watts subunits                                 |
| 34-35   | 2    | RX Power Low Alarm                | `0x00 0x08` (-31dBm)                                                                        | Value expressed in watts subunits                                 |
| 36-37   | 2    | RX Power High Warning             | `0x09 0xCF` (-6dBm)                                                                         | Value expressed in watts subunits                                 |
| 38-39   | 2    | RX Power Low Warning              | `0x00 0x0A` (-30dBm)                                                                        | Value expressed in watts subunits                                 |
| 40-45   | 6    | MAC address                       | Unique in each SFP                                                                          | Contains the mac address of the SFP, it could also be empty       |
| 46-55   | 10   | Reserved                          | `0x00 0x00 0x00...`                                                                         | Reserved                                                          |
| 56-59   | 4    | RX_PWR(4) Calibration             | `0x00 0x00 0x00 0x00`                                                                       | 4th order RSSI calibration coefficient                            |
| 60-63   | 4    | RX_PWR(3) Calibration             | `0x00 0x00 0x00 0x00`                                                                       | 3rd order RSSI calibration coefficient                            |
| 64-67   | 4    | RX_PWR(2) Calibration             | `0x00 0x00 0x00 0x00`                                                                       | 2nd order RSSI calibration coefficient                            |
| 68-71   | 4    | RX_PWR(1) Calibration             | `0x3F 0x80 0x00 0x00`                                                                       | 1st order RSSI calibration coefficient                            |
| 72-75   | 4    | RX_PWR(0) Calibration             | `0x00 0x00 0x00 0x00`                                                                       | 0th order RSSI calibration coefficient                            |
| 76-77   | 2    | TX_I(Slope) Calibration           | `0x01 0x00`                                                                                 | Slope for Bias calibration                                        |
| 78-79   | 2    | TX_I(Offset) Calibration          | `0x00 0x00`                                                                                 | Offset for Bias calibration                                       |
| 80-81   | 2    | TX_PWR(Slope) Calibration         | `0x01 0x00`                                                                                 | Slope for TX Power calibration                                    |
| 82-83   | 2    | TX_PWR(Offset) Calibration        | `0x00 0x00`                                                                                 | Offset for TX Power calibration                                   |
| 84-85   | 2    | T(Slope) Calibration              | `0x01 0x00`                                                                                 | Slope for Temperature calibration                                 |
| 86-87   | 2    | T(Offset) Calibration             | `0x00 0x00`                                                                                 | Offset for Temperature calibration, in units of 256ths °C         |
| 88-89   | 2    | V(Slope) Calibration              | `0x01 0x00`                                                                                 | Slope for VCC calibration                                         |
| 90-91   | 2    | V(Offset) Calibration             | `0x00 0x00`                                                                                 | Offset for VCC calibration                                        |
| 92-94   | 3    | Reserved                          | `0x00 0x00 0x00`                                                                            | Reserved                                                          |
| 95      | 1    | CC_DMI                            |                                                                                             | Check code for Base Diagnostic Fields (addresses 0 to 94)         |
| 96      | 1    | Temperature MSB                   |                                                                                             | Internally measured module temperature                            |
| 97      | 1    | Temperature LSB                   |                                                                                             |                                                                   |
| 98      | 1    | Vcc MSB                           |                                                                                             | Internally measured supply voltage in transceiver                 |
| 99      | 1    | Vcc LSB                           |                                                                                             |                                                                   |
| 100     | 1    | TX Bias MSB                       |                                                                                             | Internally measured TX Bias Current                               |
| 101     | 1    | TX Bias LSB                       |                                                                                             |                                                                   |
| 102     | 1    | TX Power MSB                      |                                                                                             | Measured TX output power                                          |
| 103     | 1    | TX Power LSB                      |                                                                                             |                                                                   |
| 104     | 1    | RX Power MSB                      |                                                                                             | Measured RX input power                                           |
| 105     | 1    | RX Power LSB                      |                                                                                             |                                                                   |
| 106-109 | 4    | Optional Diagnostics              | `0xFF 0xFF 0xFF 0xFF` (No support)                                                          | Monitor Data for Optional Laser temperature and TEC current       |
| 110     | 1    | Status/Control                    | `0x82` (Soft TX disable, disable laser, digital TX fault, digital RX LOS, power&data ready) | Optional Status and Control Bits                                  |
| 111     | 1    | Reserved                          | `0x00`                                                                                      | Reserved                                                          |
| 112-113 | 2    | Alarm Flags                       | `0x01 0x40`                                                                                 | Diagnostic Alarm Flag Status Bits                                 |
| 114     | 1    | Tx Input EQ control               | `0xFF` (No support)                                                                         | Tx Input equalization level control                               |
| 115     | 1    | Rx Out Emphasis control           | `0xFF` (No support)                                                                         | Rx Output emphasis level control                                  |
| 116-117 | 2    | Warning Flags                     | `0x01 0x40`                                                                                 | Diagnostic Warning Flag Status Bits                               |
| 118-119 | 2    | Ext Status/Control                | `0x00 0x00` (No support)                                                                    | Extended module control and status bytes                          |
|         |      | **GENERAL USE FIELDS**            |                                                                                             |                                                                   |
| 120-126 | 7    | Vendor Specific                   | `0x70 0x00 0x00 0x00 0x00 0x00 0x00`                                                        | Vendor specific memory addresses                                  |
| 127     | 1    | Table Select                      | `0x00`                                                                                      | Optional Page Select                                              |
|         |      | **USER WRITABLE EEPROM**          |                                                                                             |                                                                   |
| 128-190 | 63   | Reserved                          | `0xFF 0xFF 0xFF...`                                                                         | Reserved                                                          |
| 191-214 | 24   | GPON LOID or PLOAM                | Depends on the configuration of the SFP                                                     | GPON Logical ONU ID or PLOAM, depends on `GPON LOID/PLOAM switch` |
| 215-231 | 17   | GPON LPWD                         | Depends on the configuration of the SFP                                                     | GPON Logical Password                                             |
| 232     | 1    | GPON LOID/PLOAM switch            | Depends on the configuration of the SFP                                                     | `0x01` to enable LOID, `0x02` to enable PLOAM                     |
| 233-240 | 8    | GPON SN                           | Unique in each SFP                                                                          | GPON Serial Number (ME 256)                                       |
| 241-247 | 7    | Reserved                          | `0xFF 0xFF 0xFF...`                                                                         | Reserved                                                          |
| 248-255 | 8    | Vendor Control                    | `0xFF 0xFF 0xFF...` (Not used)                                                              | Vendor specific control functions                                 |
|         |      | **EXTRA EEPROM FIELDS**           |                                                                                             | **Not exposed to I2C interface**                                  |
| 256-511 | 256  | Unknown vendor specific           |                                                                                             | Probably not used in current SFPs                                 |
| 512-531 | 20   | GPON Equipment ID                 |                                                                                             | GPON Equipment ID (ME 257), may not work in some firmwares        |
| 532-535 | 4    | GPON Vendor ID                    |                                                                                             | GPON Vendor ID (ME 256 and more), may not work in some firmware   |
| 536-639 | 104  | Reserved                          |                                                                                             | Reserved                                                          |

{% include alert.html content="For more information, see the SFF-8472 Rev 11.0 specification." alert="Info" icon="svg-info" color="blue" %}

## List of firmwares and files
- [6BA1896SPLQA13 MTD0/U-Boot](https://mega.nz/file/wptjyYiS#Xj3cijX2bN0FexsZr1Wn7iRG0Wy4Z8vX0NyNBd1kBWo){: .btn } md5hash: 992b31a67c644aa68cf7f9caf956b1f9
- [6BA1896SPLQA13 MTD2/Image0](https://mega.nz/file/1kUlUbgQ#ANS9qH6wCggYshsQ3STD6gxmR_3TL-5MXfdCl5s50Nk){: .btn } md5hash: 5d46a9acc3c5ba8710887aa32b82aeb4
- [6BA1896SPLQA42 MTD0/U-Boot](https://mega.nz/file/FkswHbgL#s7-vaH65EPQ2O5vKeD3bU1_RPwzaKPOJdrCWvPQqDvc){: .btn } md5hash: 992b31a67c644aa68cf7f9caf956b1f9
- [6BA1896SPLQA42 MTD2/Image0](https://mega.nz/file/AgshDICC#md1vLN14JBF3iaNoZBqQH_zwALHmEaOk3_rDm1FfOic){: .btn } md5hash: 04533554bb0c8b997697fbc048159002

# Known Bugs
# Miscellaneous Links

- [FS.com](https://www.fs.com/it/products/133619.html)
- [General setting of lantiq](https://forum.fibra.click/d/23881-ma5671a-e-vodafone-25-gbps/64)
- [Usage GPON module SFP in Spain](https://forum.mikrotik.com/viewtopic.php?t=116364&start=300)
- [SourcePhotonics SPS-34-24T-HP-TDFO Datasheet](https://www.sourcephotonics.com/wp-content/uploads/2017/08/DS-8085-02_SPS-34-24T-HP-TDFO.pdf)