title: Zyxel PMG3000-D20B
has_children: false
alias: Ziza OP151S, T&W TW2362H-CDEL
layout: default
parent: Zyxel
---

# Hardware Specifications

|             |                                                  |
| ----------- | -----------------------------------------------  |
| Vendor      | Zyxel                                            |
| Model       | PMG3000-D20B                                     |
| Chipset     | Lantiq PEB98035                                  |
| Flash       | 8 MB                                             |
| RAM         | 64 MB                                            |
| System      | OpenWRT                                          |
| HSGMII      | Yes                                              |
| Optics      | SC/APC                                           |
| IP address  | 10.10.1.1                                        |
| Web Gui     | ✅ username `admin` or `guest`, password `1234` or `guest` |
| SSH         | ✅ username `admin`, password `admin` |
| Form Factor | miniONT SFP                                      |

{% include image.html file="pmg3000-d20b.png" alt="PMG3000-D20B" caption="PMG3000-D20B" %}
{% include image.html file="op151s.png" alt="Ziza OP151S" caption="Ziza OP151S" %}

Once you access the stick via ssh you will be presented with a second tier login. The credentials to access the zyxel shell are: username: `twmanu` , password: `twmanu`.
From the Zyxel shell you can move to a standard Linux shell using the `linuxshell` command

## Firmware is interchangeable with:

- [Halny HL-GSFP](/ont-halny-hl-gsfp)
- [D-LINK DPN-100-Rev-A2](/ont-d-link-dpn-100-rev-a2)
- [Ziza OP151s](/ont-ziza-op151s)
- [T&W TW2362H-CDEL](/ont-t-w-tw2362h-cdel)

# List of software versions

# List of partitions
 
| dev  | size     | erasesize | name           |
| ---- | -------- | --------- | -------------- |
| mtd0 | 00060000 | 00010000  | "Boot"         |
| mtd1 | 00010000 | 00010000  | "Env"          |
| mtd2 | 00390000 | 00010000  | "ImageA"       |
| mtd3 | 00390000 | 00010000  | "ImageB"       |
| mtd4 | 00060000 | 00010000  | "Config"       |
| mtd5 | 00010000 | 00010000  | "SECTION_EGIS" |
| mtd6 | 00250000 | 00010000  | "rootfs"       |
| mtd7 | 00020000 | 00010000  | "rootfs_data"  |


This stick supports dual boot, as visible from the presence of `ImageA` and `ImageB`, which contain the rootfs.


# List of firmwares and files
## Useful files
- `/var/config/ont.sys` - Used to customize various settings on the stick. If you don't have it you can copy the stock one from /ont.sys

# Useful Commands
{% include alert.html content="All commands start from the twmanu shell." alert="Note"  icon="svg-info" color="blue" %}

## Changing the ONT's S/N
{% include alert.html content="The S/N is stored in the ASCII format." alert="Note"  icon="svg-info" color="blue" %}
```sh
manufactory
set sn ALCLf0f0f0f0
exit
hal
set sn ALCLf0f0f0f0
```

## Changing the ONT's PLOAM password
{% include alert.html content="The PLOAM password is stored in the ASCII format." alert="Note"  icon="svg-info" color="blue" %}
This can be done easily via web ui. If you prefer to do it via the shell use:
```sh
hal
set password PLOAMPASS
```

## Changing the ONT's equipment ID
{% include alert.html content="Model number must not be more than 20 characters long in total." alert="Note"  icon="svg-info" color="blue" %}
```sh
manufactory
set equipment id MYEQUIPMENTID
exit
omci
equipment id MYEQUIPMENTID
```

## Changing the ONT's hardware version
```sh
manufactory
set hardware version 3FE49165BFAA01
```

## Changing the software version
Edit the /var/config/ont.sys via vi directly on the stick itself. The file is CRLF terminated, one entry per line.
The entries for the software version are:
```
SW_VER0:0xabcdef
SW_VER1:0xabcedf
```
{% include alert.html content="It's better to enter the software version in hex format, all lowercase precedeed by 0x." alert="Note"  icon="svg-info" color="blue" %}

## See link speed
This SFP has HSGMII enabled by default: `link_status=5` for HSGMII 2.5Gbit, `link_status=4` for SGMII 1Gbit:
```
linuxshell
onu lanpsg 0
```

## Checking connection state
To see the connection state use the following command:
```
linuxshell
onu ploamsg
```

`curr_state=5` for O5 state, `curr_state=1` for all other operational states.

## Querying a particular OMCI ME
Query via OMCI ME Class Name
```sh
omci
show me classname OmciClassName (e.g Ont2g)
```

Query via OMCI ME ID
```sh
omci
show me classid OmciClassId (e.g 7)
```


# Low Level Modding

## Creating a new rootfs
The stick has a tricky image packing method, fortunately it has been reverse engineered. A script to help you create a custom rootfs can be found here: [https://github.com/nanomad/zyxel-pmg-3000-mod-kit](https://github.com/nanomad/zyxel-pmg-3000-mod-kit)

## Flashing a new rootfs
{% include alert.html content="All commands start from the twmanu shell." alert="Note"  icon="svg-info" color="blue" %}

- Transfer the new mtd on the stick via tftp
```
linuxshell
tftp -gr mtd2.mod.bin TFTP_SERVER_IP
```
- Flash it on the standby partition. 
You can use `system` and then `show actimage` to get the current active image. Check `/proc/mtd` for the right mtds. Usually:
- if the currect active image is A the mtd in use is mtd2
- If the current active image is B the mtd in use is mtd3
```
linuxshell
mtd -e /dev/mtd2 write /tmp/mtd2.mod.bin /dev/mtd2
```
- Switch to the new image
```
system
set actimage a
```
- Reboot the ONT
```
system
reboot
```

# Reset Web Gui admin credentials

Sometimes, under certain circumstances, the Web Gui admin credentials might get changed from the default `admin`/`1234` combination.
To restore the default combination you can try following [this method](https://github.com/xvzf/zyxel-gpon-sfp/issues/6#issuecomment-1065864650).

## EEPROM (I2C slave simulated EEPROM)
The Zyxel PMG3000-D20B does not have a physical EEPROM, the Falcon SOC emulates an EEPROM by exposing it on the I2C interface as required by the SFF-8472 specification.

On the I2C interface there will be two memories of 256 bytes each at the addresses `1010000X (A0h)` and `1010001X (A2h)`.

The Zyxel PMG3000-D20B stores the content of the emulated EEPROM1 (A2h) in `/tmp/config/sfp_eeprom1` to restore it after a reboot.

{% include alert.html content="The contents of EEPROM0 (A0h) are not stored anywhere and is regenerated at each boot" alert="Info" icon="svg-info" color="blue" %}

### EEPROM0 layout

| address   | size     | name                              | default value                                                                                           | description                                                         |
| --------- | -------- | --------------------------------- | ------------------------------------------------------------------------------------------------------- | ------------------------------------------------------------------- |
|           |          | **BASE ID FIELDS (SFF-8472)**     |                                                                                                         |                                                                     |
| 0         | 1        | Identifier                        | `0x03` (SFP)                                                                                            | Type of transceiver                                                 |
| 1         | 1        | Ext identifier                    | `0x04` (MOD_DEF 4)                                                                                      | Additional information about the transceiver                        |
| 2         | 1        | Connector                         | `0x01` (SC)                                                                                             | Type of media connector                                             |
| 3-10      | 8        | Transceiver                       | `0x04 0x40 0x00 0x02 0x12 0x10 0x00 0x80` (1X LX, 1310TX SMF, 1000BASE-LX, 1200 Mbps)                   | Code for optical compatibility                                      |
| 11        | 1        | Encoding                          | `0x03` (8B/10B)                                                                                         | High speed serial encoding algorithm                                |
| 12        | 1        | Signaling Rate, Nominal           | `0x0C` (1Gbps)                                                                                          | Nominal signaling rate                                              |
| 13        | 1        | Rate Identifier                   | `0x00` (Not used)                                                                                       | Type of rate select functionality                                   |
| 14        | 1        | Length (SMF,km)                   | `0x14` (20 km)                                                                                          | Link length supported for single-mode fiber, units of km            |
| 15        | 1        | Length (SMF)                      | `0xC8` (200 x 100m)                                                                                     | Link length supported for single-mode fiber, units of 100 m         |
| 16        | 1        | Length (50 um, OM2)               | `0xFF` (No support)                                                                                     | Link length supported for 50 um OM2 fiber, units of 10 m            |
| 17        | 1        | Length (62.5 um, OM1)             | `0xFF` (No support)                                                                                     | Link length supported for 62.5 um OM1 fiber, units of 10 m          |
| 18        | 1        | Length copper cable               | `0x00` (No support)                                                                                     | Link length supported for copper or direct attach cable, units of m |
| 19        | 1        | Length (50 um, OM3)               | `0xFF` (No support)                                                                                     | Link length supported for 50 um OM3 fiber, units of 10 m            |
| 20-35     | 16       | Vendor name                       | `0x4C 0x61 0x6E 0x74 0x69 0x71 0x20 0x20 0x20 0x20 0x20 0x20 0x20 0x20 0x20 0x20` (Lantiq)              | SFP vendor name (ASCII)                                             |
| 36        | 1        | Transceiver                       | `0x00` (No support)                                                                                     | Code for optical compatibility                                      |
| 37-39     | 3        | Vendor OUI                        | `0x00 0x1C 0xAD`                                                                                        | SFP vendor IEEE company ID                                          |
| 40-55     | 16       | Vendor PN                         | `0x50 0x61 0x72 0x74 0x20 0x4E 0x75 0x6D 0x62 0x65 0x72 0x20 0x20 0x20 0x20 0x20` (Part Number)         | Part number provided by SFP vendor (ASCII)                          |
| 56-59     | 4        | Vendor rev                        | `0x30 0x30 0x30 0x30` (0000)                                                                            | Revision level for part number provided by vendor (ASCII)           |
| 60-61     | 2        | Wavelength                        | `0x05 0x1E` (1310nm TX)                                                                                 | Laser wavelength                                                    |
| 62        | 1        | Fibre Channel Speed 2             | `0xFF` (No support)                                                                                     | Transceiver's Fibre Channel speed capabilities                      |
| 63        | 1        | CC_BASE                           |                                                                                                         | Check code for Base ID Fields (addresses 0 to 62)                   |
|           |          | **EXTENDED ID FIELDS (SFF-8472)** |                                                                                                         |                                                                     |
| 64-65     | 2        | Options                           | `0x00 0x1A` (TX DISABLE, TX FAULT, RX LOS)                                                              | Indicates which optional transceiver signals are implemented        |
| 66        | 1        | Signaling Rate, max               | `0x00` (No specified)                                                                                   | Upper signaling rate margin, units of %                             |
| 67        | 1        | Signaling Rate, min               | `0x00` (No specified)                                                                                   | Lower signaling rate margin, units of %                             |
| 68-83     | 16       | Vendor SN                         | `0x6E 0x6F 0x20 0x73 0x65 0x72 0x69 0x61 0x6C 0x20 0x6E 0x75 0x6D 0x62 0x65 0x72` (no serial number)    | Serial number provided by vendor (ASCII)                            |
| 84-91     | 8        | Date code                         | `0x31 0x33 0x30 0x31 0x30 0x31 0x20 0x20` (130101)                                                      | Vendor's manufacturing date code                                    |
| 92        | 1        | Diagnostic Monitoring Type        | `0x6C` (Digital diagnostic, Internally calibrated, Received average power type, address change)         | Indicates which type of diagnostic monitoring is implemented        |
| 93        | 1        | Enhanced Options                  | `0xF0` (Alarm/warning flags, soft TX_DISABLE control, soft TX_FAULT monitoring, soft RX_LOS monitoring) | Indicates which optional enhanced features are implemented          |
| 94        | 1        | SFF-8472 Compliance               | `0x05` (Rev 11.0 of SFF-8472)                                                                           | Indicates which revision of SFF-8472 the transceiver complies with  |
| 95        | 1        | CC_EXT                            |                                                                                                         | Check code for the Extended ID Fields (addresses 64 to 94)          |
|           |          | **VENDOR SPECIFIC FIELDS**        |                                                                                                         |                                                                     |
| 96-127    | 32       | Vendor data                       | `0x20 0x20 0x20...` (Not used)                                                                          | Vendor specifc data (ASCII)                                         |
| 128-255   | 128      | Reserved                          | `0x00 0x00 0x00...`                                                                                     | Reserved                                                            |

### EEPROM1 layout

| address   | size     | name                              | default value                                                                               | description                                                         |
| --------- | -------- | --------------------------------- | ------------------------------------------------------------------------------------------- | ------------------------------------------------------------------- |
|           |          | **DIAGNOSTIC AND CONTROL FIELDS** |                                                                                             |                                                                     |
| 0-1       | 2        | Temp High Alarm                   | `0x64 0x00` (100℃)                                                                         |                                                                     |
| 2-3       | 2        | Temp Low Alarm                    | `0xCE 0x00` (-50℃)                                                                         |                                                                     |
| 4-5       | 2        | Temp High Warning                 | `0x55 0x00` (85℃)                                                                          |                                                                     |
| 6-7       | 2        | Temp Low Warning                  | `0xD8 0x00` (-40℃)                                                                         |                                                                     |
| 8-9       | 2        | Voltage High Alarm                | `0x8C 0xA0` (3.6V)                                                                          |                                                                     |
| 10-11     | 2        | Voltage Low Alarm                 | `0x75 0x30` (3.0V)                                                                          |                                                                     |
| 12-13     | 2        | Voltage High Warning              | `0x88 0xB8` (3.5V)                                                                          |                                                                     |
| 14-15     | 2        | Voltage Low Warning               | `0x79 0x18` (3.1V)                                                                          |                                                                     |
| 16-17     | 2        | Bias High Alarm                   | `0xAF 0xC8` (90mA)                                                                          |                                                                     |
| 18-19     | 2        | Bias Low Alarm                    | `0x00 0x00` (0mA)                                                                           |                                                                     |
| 20-21     | 2        | Bias High Warning                 | `0x88 0xB8` (70mA)                                                                          |                                                                     |
| 22-23     | 2        | Bias Low Warning                  | `0x00 0x00` (0mA)                                                                           |                                                                     |
| 24-25     | 2        | TX Power High Alarm               | `0x7B 0x86` (5dBm)                                                                          | Value expressed in watts subunits                                   |
| 26-27     | 2        | TX Power Low Alarm                | `0x27 0x10` (0dBm)                                                                          | Value expressed in watts subunits                                   |
| 28-29     | 2        | TX Power High Warning             | `0x6E 0x17` (4dBm)                                                                          | Value expressed in watts subunits                                   |
| 30-31     | 2        | TX Power Low Warning              | `0x2B 0xD4` (0.1dBm)                                                                        | Value expressed in watts subunits                                   |
| 32-33     | 2        | RX Power High Alarm               | `0x07 0xCB` (-7dBm)                                                                         | Value expressed in watts subunits                                   |
| 34-35     | 2        | RX Power Low Alarm                | `0x00 0x0F` (-28dBm)                                                                        | Value expressed in watts subunits                                   |
| 36-37     | 2        | RX Power High Warning             | `0x06 0x30` (-8dBm)                                                                         | Value expressed in watts subunits                                   |
| 38-39     | 2        | RX Power Low Warning              | `0x00 0x14` (-27dBm)                                                                        | Value expressed in watts subunits                                   |
| 40-55     | 16       | Reserved                          | `0x00 0x00 0x00...`                                                                         | Contains the mac address of the SFP, it could also be empty         |
| 56-59     | 4        | RX_PWR(4) Calibration             | `0x00 0x00 0x00 0x00`                                                                       | 4th order RSSI calibration coefficient                              |
| 60-63     | 4        | RX_PWR(3) Calibration             | `0x00 0x00 0x00 0x00`                                                                       | 3rd order RSSI calibration coefficient                              |
| 64-67     | 4        | RX_PWR(2) Calibration             | `0x00 0x00 0x00 0x00`                                                                       | 2nd order RSSI calibration coefficient                              |
| 68-71     | 4        | RX_PWR(1) Calibration             | `0x00 0x00 0x00 0x00`                                                                       | 1st order RSSI calibration coefficient                              |
| 72-75     | 4        | RX_PWR(0) Calibration             | `0x00 0x00 0x00 0x00`                                                                       | 0th order RSSI calibration coefficient                              |
| 76-77     | 2        | TX_I(Slope) Calibration           | `0x00 0x00`                                                                                 | Slope for Bias calibration                                          |
| 78-79     | 2        | TX_I(Offset) Calibration          | `0x00 0x00`                                                                                 | Offset for Bias calibration                                         |
| 80-81     | 2        | TX_PWR(Slope) Calibration         | `0x00 0x00`                                                                                 | Slope for TX Power calibration                                      |
| 82-83     | 2        | TX_PWR(Offset) Calibration        | `0x00 0x00`                                                                                 | Offset for TX Power calibration                                     |
| 84-85     | 2        | T(Slope) Calibration              | `0x00 0x00`                                                                                 | Slope for Temperature calibration                                   |
| 86-87     | 2        | T(Offset) Calibration             | `0x00 0x00`                                                                                 | Offset for Temperature calibration, in units of 256ths °C           |
| 88-89     | 2        | V(Slope) Calibration              | `0x00 0x00`                                                                                 | Slope for VCC calibration                                           |
| 90-91     | 2        | V(Offset) Calibration             | `0x00 0x00`                                                                                 | Offset for VCC calibration                                          |
| 92-94     | 3        | Reserved                          | `0x00 0x00 0x00`                                                                            | Reserved                                                            |
| 95        | 1        | CC_DMI                            |                                                                                             | Check code for Base Diagnostic Fields (addresses 0 to 94)           |
| 96        | 1        | Temperature MSB                   |                                                                                             | Internally measured module temperature                              |
| 97        | 1        | Temperature LSB                   |                                                                                             |                                                                     |
| 98        | 1        | Vcc MSB                           |                                                                                             | Internally measured supply voltage in transceiver                   |
| 99        | 1        | Vcc LSB                           |                                                                                             |                                                                     |
| 100       | 1        | TX Bias MSB                       |                                                                                             | Internally measured TX Bias Current                                 |
| 101       | 1        | TX Bias LSB                       |                                                                                             |                                                                     |
| 102       | 1        | TX Power MSB                      |                                                                                             | Measured TX output power                                            |
| 103       | 1        | TX Power LSB                      |                                                                                             |                                                                     |
| 104       | 1        | RX Power MSB                      |                                                                                             | Measured RX input power                                             |
| 105       | 1        | RX Power LSB                      |                                                                                             |                                                                     |
| 106-109   | 4        | Optional Diagnostics              | `0x00 0x00 0x00 0x00` (No support)                                                          | Monitor Data for Optional Laser temperature and TEC current         |
| 110       | 1        | Status/Control                    | `0x02` (Digital RX LOS)                                                                     | Optional Status and Control Bits                                    |
| 111       | 1        | Reserved                          | `0x00`                                                                                      | Reserved                                                            |
| 112-113   | 2        | Alarm Flags                       | `0x01 0x40`                                                                                 | Diagnostic Alarm Flag Status Bits                                   |
| 114       | 1        | Tx Input EQ control               | `0x00` (No support)                                                                         | Tx Input equalization level control                                 |
| 115       | 1        | Rx Out Emphasis control           | `0x00` (No support)                                                                         | Rx Output emphasis level control                                    |
| 116-117   | 2        | Warning Flags                     | `0x01 0x40`                                                                                 | Diagnostic Warning Flag Status Bits                                 |
| 118-119   | 2        | Ext Status/Control                | `0x00 0x00` (No support)                                                                    | Extended module control and status bytes                            |
|           |          | **GENERAL USE FIELDS**            |                                                                                             |                                                                     |
| 120-126   | 7        | Vendor Specific                   | `0x00 0x00 0x00 0x00 0x00 0x00 0x00`                                                        | Vendor specific memory addresses                                    |
| 127       | 1        | Table Select                      | `0x00`                                                                                      | Optional Page Select                                                |
|           |          | **USER WRITABLE EEPROM**          |                                                                                             |                                                                     |
| 128-232   | 105      | Reserved                          | `0x00 0x00 0x00...`                                                                         | Reserved                                                            |
| 233-240   | 8        | GPON SN                           | Unique in each SFP                                                                          | GPON Serial Number (ME 256)                                         |
| 241-247   | 7        | Reserved                          | `0x00 0x00 0x00...`                                                                         | Reserved                                                            |
| 248-255   | 8        | Vendor Control                    | `0x00 0x00 0x00...` (Not used)                                                              | Vendor specific control functions                                   |

{% include alert.html content="For more information, see the SFF-8472 Rev 11.0 specification." alert="Info" icon="svg-info" color="blue" %}

# Known Bugs
- [Not working with Broadcom BCM57810S](https://github.com/xvzf/zyxel-gpon-sfp/issues/10)
- Issue on IPv6 discovery. But we are not sure if is a edge case of a particular ISP or not
- [Some sticks have a custom password](https://github.com/xvzf/zyxel-gpon-sfp/issues/6)


# Miscellaneous Links

- [zyxel gpon- sfp](https://github.com/xvzf/zyxel-gpon-sfp)
- [zyxel pmg-3000 mod kit](https://github.com/nanomad/zyxel-pmg-3000-mod-kit)